1. Guides
  2. Timber framed
Timber-framed houses

The Faculty House

The Faculty house is a timber-framed house from the 1960s, a period of new approaches to housing driven by demand for affordable homes. It was manufactured by Dudley Coles Long…

  • 4 min read
  • Updated
  • Flettons Surveyors
The Faculty House

Overview

The Faculty house is a timber-framed house from the 1960s, a period of new approaches to housing driven by demand for affordable homes. It was manufactured by Dudley Coles Long Ltd and designed by the architects Louis De Soissons, Robertson & Fraser.

Faculty houses are two-storey semi-detached or terraced houses. Much of their construction is not documented, which makes inspection more demanding than for better-recorded types.

The Faculty House

Typical characteristics & construction

The external walls are timber frame panels clad separately with brick, stone or horizontal boarding. On the front and rear the cladding is brick up to first floor level with horizontal boarding above. The separating walls between houses are 11-inch cavity masonry, which gives sound insulation and fire resistance.

The ground floor is concrete, the first floor is chipboard on timber joists, and ceilings are plasterboard. Details of the substructure are not documented, and the roof construction is not known beyond its medium pitch and tile covering.

Element Typical construction Inspection focus
Substructure Not documented Signs of movement
External walls Timber frame panels clad separately with brick, stone or horizontal boarding Rot, insect damage, elevated moisture; cracks, loose materials, water damage to cladding
Separating walls 11-inch cavity masonry Movement or cracking
Floors Concrete ground floor; chipboard on timber joists at first floor General condition
Ceilings Plasterboard Cracks from movement
Roof Medium pitch, tiled; structure not known Missing or damaged tiles, soundness of the structure

Potential hazards & inspection priorities

Primary concern: the timber frame and moisture

Over time the timber frame is susceptible to rot and insect infestation, particularly where it has not been properly maintained. The design of the external walls also allows moisture in, causing dampness and structural damage if it is not dealt with promptly. The timber frame should be inspected for rot, insect damage and other deterioration, and a moisture meter used to check for elevated moisture levels. The brick, stone or boarding should be examined for cracks, loose materials and signs of water damage.

Secondary concerns: movement, damp and mould

Given the age of these houses, structural movement occurs and shows as cracks in walls and ceilings. The cavity masonry separating walls should be checked for movement or cracking, which can point to structural issues. Poor ventilation and moisture ingress lead to dampness and mould, which affect both the structure and the health of occupants.

The roof construction is not documented, but the tiles should be checked for missing or damaged units and the structure confirmed as sound.

Long-term considerations: insulation and services

Faculty houses do not meet modern thermal insulation standards, which means higher energy costs. An energy efficiency assessment shows whether upgrades to insulation are needed. Many have outdated electrical systems that need upgrading to meet current safety standards, and old plumbing leads to leaks and water damage that call for repair or replacement.

Is this house right for you?

The Faculty house is a distinctive 1960s type with its own challenges, not least how little is recorded about parts of its construction.

  • Commission a full building survey
  • Have the timber frame and external walls checked for rot, insect damage and moisture
  • Look for structural movement, damp and mould
  • Allow for upgrading insulation, electrics and plumbing

Understanding the construction, hazards and inspection requirements is what allows a buyer to make an informed decision.

Mortgage & resale considerations

Faculty houses are not designated defective under the Housing Defects Act 1984, but they do have common issues that buyers should be mindful of.

For the surveyor, the Building Research Establishment (BRE) provides guidance in "Timber frame housing 1920–1975: inspection and assessment" (BR 282) and in its supplementary guidance on the examination and interpretation of timber-framed houses (GBG 11 and GBG 12).

What a survey can — and cannot — tell you

A building survey provides an informed assessment of the visible condition and construction of a Faculty house. Inspections are non-intrusive and limited to areas that are accessible at the time of inspection.

  • Identify visible cracking, loose materials and water damage to the external walls
  • Take moisture meter readings to check for elevated moisture
  • Assess signs of movement, dampness, mould and condensation risk
  • Comment on roof tiles and the general condition of services
  • Highlight defects that may require repair, monitoring, or further investigation

However, there are limitations to what a survey can determine without intrusive investigation.

  • Confirm the condition of the timber frame concealed behind the cladding
  • Establish the undocumented substructure and roof construction where not visible
  • Determine the full extent of any concealed rot or insect damage
  • Inspect areas that are inaccessible or covered at the time of inspection

Where higher-risk indicators are identified, further specialist or intrusive investigation may be recommended.

Buying a non-traditional home?

See how it was built, and what it needs.

A Level 3 Building Survey looks closely at the structure and condition of the home, records what could and could not be seen, and sets out clear next steps by trade and timing.

Level 3 Building Survey From £595

Get my survey & price What Level 3 covers

  • RICS-regulated firm of surveyors
  • Condition ratings for every part of the home
  • Plain-English advice on what to do next