Overview
The Orlit Type I house is a precast reinforced concrete (PRC) house built mainly in the late 1940s and the 1950s to address the housing shortage that followed the Second World War, when homes were needed quickly and economically. The houses were manufactured by Orlit Ltd, a company that played a significant role in the development of system-built housing in that period.
Approximately 17,000 Orlit houses had been built by 1956, about 9,000 of them in England and Wales, 5,600 in Scotland and 2,800 in Northern Ireland, which makes them a common sight in parts of the UK. They are usually found in suburban areas and were designed to be functional and economical, built as bungalows and as two-storey semi-detached and terraced houses.

Typical characteristics & construction
The house stands on pad foundations with precast concrete stub columns cast into them. The frame is made up of three main cross frames running from front to back of the house: 5½-inch square PRC columns in storey-height sections joined by bolted steel plates above each floor, and 8-inch precast concrete main beams at first floor and roof level. The main beams are joined to brackets on the columns by joints of concrete cast on site, known as stitches; some stitches were made with ordinary Portland cement (OPC) concrete and some with high alumina cement (HAC) concrete. Precast secondary beams, about 7 by 4 inches at 4-foot centres, span between the main frames and carry the floors and the roof. The columns sit within the wall cavity, so in a finished house almost the whole frame is hidden. The external and internal block walls, not the concrete frame, give the house its overall stability.
The external walls are built from 2-inch precast concrete base bonding units and 2-inch precast concrete slabs, a cavity, then 2½-inch lightweight precast concrete slabs and plasterboard on timber framing, tied with galvanised mild steel wall ties. The separating wall is a PRC frame cavity wall infilled with foamed slag aggregate concrete blocks, and internal partitions are lightweight concrete slabs.
The ground floor is concrete. The first floor is timber boarding on timber beams carried on the PRC secondary beams, and ceilings are plasterboard. The roof is formed with PRC beams spanning between internal columns and inverted PRC trough-shaped units with concrete fill, with timber wall plates, timber trusses and purlins, and tiles. Many houses instead have a flat roof, which was the most common form, of 2-inch precast concrete slabs resting on the secondary beams, with a screed to falls, asphalt or bituminous felt, and precast eaves units.
| Element | Typical construction | Inspection focus |
|---|---|---|
| Substructure | Pad foundations with PC stub columns cast in | Signs of movement |
| Frame | 5½-inch PRC columns with bolted steel plate joints; PRC main beams joined by cast-in-place OPC or HAC stitches; 7 by 4-inch PRC secondary beams | Cracking, spalling, exposed reinforcement, OPC and HAC stitches, secondary beams |
| External walls | PC base bonding units and PC slabs, cavity, lightweight PC slabs, plasterboard on timber framing; galvanised MS ties | Cracking, spalling, compromised cover, wall tie corrosion |
| Separating wall | PRC frame cavity wall infilled with foamed slag aggregate blocks | Cracking, deterioration |
| Floors | Concrete ground floor; timber boarding on timber beams on PRC secondary beams | Cracking, unevenness, sagging, moisture |
| Ceilings and partitions | Plasterboard ceilings; lightweight concrete slab partitions | Cracking, sagging, water staining |
| Roof | PRC beams and inverted trough units, timber trusses and purlins, tiles; or flat roof of PRC eaves units, screed, asphalt or felt | Missing or broken tiles, cracked coverings, sagging, condition of PRC beams and trusses |
Potential hazards & inspection priorities
Primary concern: the PRC frame
The condition of the concealed PRC frame is the main concern with this type. Where the concrete has carbonated to the depth of the steel, or contains chloride, the reinforcement corrodes and the concrete cracks and spalls. Because the house's stability comes from its walls rather than its frame, the investigators considered overall collapse of an Orlit house from reinforcement corrosion highly unlikely. The local risks are more specific. A badly cracked main beam matters most where there is no block wall beneath it to take the load. Under a flat roof, the concrete roof slabs simply rest on the secondary beams, so a failed secondary beam there is a greater concern than one under a timber floor or pitched roof. Spalled concrete can fall from cracked cladding, especially the corner units, door canopies and chimneys. The published investigation of Orlit houses, carried out in 1983, examined 16 houses in detail in England, Scotland and Northern Ireland, and consulting engineers inspected a further 66; the houses offered were mostly ones that had fallen vacant, so the sample was not necessarily typical. Cracked structural components were found in 10 of the 14 houses examined. The secondary beams were in the poorest condition, with 16 of the 22 examined cracked by corroding reinforcement, worst in flat roofs suffering from leaks or condensation; cover to their steel varied widely, from 5 to 50 mm, and carbonation had generally reached it. The main beams were generally uncracked, with substantial cracking in only one. Some stitches were cracked, and very low quality HAC concrete was found in some. The seven columns examined were uncracked and were expected to prove the most durable part of the frame. Chloride, at medium or high levels, was present in about half of the components sampled. Cracking and spalling of cladding, corner units, window surrounds, door canopies, eaves soffit units and chimneys was common. No structurally unsafe conditions were found, but in some cases early remedial action was desirable, and in one house the deterioration was serious enough for the tenants to be moved out. Those findings describe the houses examined then, not the present condition of any house today.
Cast on site, the stitches are likely to be of lower quality than the precast parts, and HAC stitches in particular can deteriorate badly in damp conditions. Where the secondary beams can be seen, for example from a pitched roof space, they should be examined for cracking along their length and at their ends where they bear on the main beams. Outside, the corner cladding units, cladding panels, window surrounds, door canopies, eaves soffits and chimneys should be checked for cracking and spalling, and the top row of panels on pitched-roof houses for bowing or leaning out.
Secondary concerns: walls, wall ties and moisture
The external walls should be checked for cracking and spalling, and for places where the concrete cover has failed and the reinforcement is exposed. The galvanised mild steel wall ties corrode over time and weaken the structure.
Moisture and water damage have a significant effect on the structure, because water ingress weakens the concrete and reinforcement and speeds up cracking, spalling and deterioration. Damp patches, mould and water stains on the roof, walls, floors and ceilings are the signs to look for. Mould and mildew are also a health risk to occupants.
Long-term consideration: the roof and floors
The roof needs checking for missing or broken tiles, cracks in asphalt or felt, and sagging or uneven areas, with attention to the PRC beams and timber trusses. Floors and ceilings should be checked for cracking, sagging and unevenness, and for any sign that the PRC beams above or below are deteriorating.
Is this house right for you?
The Orlit Type I house is a significant example of post-war British housing, but its PRC components have proved susceptible to structural problems over time. The houses may not meet modern building standards and can require significant repairs or modifications to make them safe and habitable.
- Commission a full building survey
- Obtain previous inspection reports, maintenance records and building plans where available
- Establish the condition of the PRC columns, beams, stitches and secondary beams first
- Check for water ingress through the roof, walls, floors and ceilings
Thorough inspection and prompt attention to any issues are what secure the safety and longevity of an Orlit Type I house.
Mortgage & resale considerations
Orlit Type I houses are designated defective under the Housing Defects Act 1984, whose provisions for England and Wales are now in Part XVI of the Housing Act 1985. Where Orlit Type I houses were designated in Scotland, the designation was repealed from 30 July 2018. That designation is the central point to understand before buying, and it means the house may need significant repairs or modifications to be safe and habitable.
What a survey can — and cannot — tell you
A building survey provides an informed assessment of the visible condition and construction of an Orlit Type I house. Inspections are non-intrusive and limited to areas that are accessible at the time of inspection.
- Identify visible cracking, spalling and exposed reinforcement to accessible PRC components
- Assess signs of dampness, mould, water staining and moisture ingress
- Comment on roof coverings and the external envelope
- Review the general condition of accessible floors, ceilings and partitions
- Highlight defects that may require repair, monitoring, or further investigation
However, there are limitations to what a survey can determine without intrusive investigation.
- Measure reinforcement cover, carbonation depth or chloride content
- Confirm the condition of columns, beams and stitches concealed by finishes and linings
- Assess the condition of wall ties within the cavity
- Inspect areas that are inaccessible or covered at the time of inspection
Where higher-risk indicators are identified, further specialist investigation may be recommended. Because cracking of the beams and columns is hidden from a normal survey, that usually means looking into the cavities and ceiling voids with an optical probe, or removing small areas of ceiling, floorboards or inner blockwork to see the main beams, stitches, secondary beams and columns, and taking concrete samples to measure carbonation and chloride and to test for HAC. Flat roofs with a history of damp, and main beams with no wall beneath them, are the first priorities. Repairs can include replacing secondary beams, replacing or strengthening internal main beams and their stitches, and replacing the corner cladding units full height; replacing columns and beams within the external and party walls is highly disruptive. This is separate from the survey itself: a survey is non-invasive, and any opening up, sampling or testing is a specialist investigation arranged afterwards, with the owner's permission.